HOFMANN
Thermal engineering
Deutsch
English
+43 7215 36 01
ISO 9001 : 2015
  • Industrial furnaces
    • Drying ovens with air circulation
    • Continuous furnaces
    • Overhead furnaces
    • Bogie hearth furnaces
    • Chest ovens
    • Pressing furnaces
    • Cable preheating furnaces
    • Chamber furnaces, Firing furnaces & Double door furnaces
    • Shaft furnaces & Crucible furnaces
    • Furnaces for welding consumables
  • Ovens in stock
  • References
    • Customers
    • Furnace systems
      • Drying ovens with air circulation
      • Continuous ovens
      • Overhead ovens
      • Bogie hearth furnaces
      • Chest ovens
      • Press ovens
      • Cable preheating ovens
      • Chamber kilns, kilns & double-door kilns
      • Pit furnaces & crucible furnaces
      • Furnaces for welding consumables
  • News
  • Company
    • History
    • Team
  • Career
  • Request
  • Contact

References - Oven systems

  • References
  • Furnace systems

Examples and references of our furnace systems

Drying ovens with air circulation

Air circulation furnace for heat treatment TSL P4

Technical data
Area of applicationFoundry industry
BatchAluminum parts
Max. Oven temperature250
Max. Working temperature150 - 220
Temperature accuracy:+ / - 3 K
External dimensions: W x H x D:3634 x 3595 x 1941 mm
Usable dimensions of the oven chamber w x h x d:2000 x 2104 x 1314 mm
Useful volume of the oven chamber:5,5 m³
Heating device / heating capacity:66 kW
Fan unit / motor power:1 piece; 7.5 kW

Three air circulation ovens for heat treatment TSL P2

Technical data
Area of application:Foundry industry
Batch:Aluminum parts
Max. oven temperature:250 °C
Max. working temperature:230 °C
Temperature accuracy:+ / - 5 K
External dimensions: W x H x D:3070 x 3840 x 2956 mm
Usable dimensions of the oven chamber w x h x d:1100 x 1800 x 1300 mm
Useful volume of the oven chamber:2,6 m³
Heating device / heat output:66 kW
Fan unit / motor power:1 piece; 5.5 kW

Air circulation furnace for heat treatment TSL S

Technical data
Area of application:Graphite industry
Batch:Graphite parts
Max. oven temperature:400 °C
Max. working temperature:350 °C
Temperature accuracy:+ / - 3 K
External dimensions: W x H x D:3720 x 3600 x 1990 mm
Special featureTwo oven chambers in one oven
Useful dimensions of an oven chamber w x h x d:650 x 2100 x 1250 mm
Useful volume of an oven chamber:1,7 m³
Heating device / heat output:42 kW
Fan unit / motor power:1 piece; 7.5 kW
Shielding gasNitrogen

Air circulation furnace according to AMS

Technical data

Scope:Aviation Industry
Temperature:90 °C bis 650 °C
Batch dimensions: L x W x H:400 x 400 x 300 mm
Temperature accuracy:+/- 2 K
LoremLipsum

Heat treatment furnace TSL S

Technical data
Scope:Heat treatment
Charge:Measuring transducer
Temperature:100 °C bis 250 °C
Useful dimensions:800 x 1000 x 750 mm
Batch weight:up to 250 kg
LoremLipsum

Chamber furnace system for annealing Teflon coatings on steel rolls

Technical data
max. oven temperature:400 °C
max. working temperature:360 °C
External dimensions: L(D) x W x H:4050 x 3400 x 4300 mm
Usable dimensions of the furnace chamber (d) x w x h:3100 x 2280 x 2430 mm
Usable volume of the furnace chambers:17,2 m³
Heating device / heating power:152 kW
Fan unit / motor power:2 pieces 5,5 kW
LoremLipsum

Laboratory furnace for aluminum sample parts according to AMS 2750

Technical data
max. oven temperature:620 °C
max. working temperature:600 °C
External dimensions: L(D) x W x H:2130 x 3005 x 2010 mm
Usable dimensions of the furnace chamber (d) x w x h:750 x 750 x 1100 mm
Usable volume of the furnace chambers:0,62 m³
Heating device / heating power:150 kW
Fan unit / motor power:5,5 kW
LoremLipsum

Air circulation furnace for heat treatment of steel parts

Technical data
max. oven temperature:600 °C
max. working temperature:540 °C
External dimensions: L(D) x W x H:1860 x 2132 x 1740 mm
Usable dimensions of the furnace chamber (d) x w x h:800 x 800 x 750 mm
Usable volume of the furnace chambers:0,5 m³
Heating device / heating power:42 kW
Fan unit / motor power:0,75 / 4 kW
LoremLipsum

Hot calibration furnace

Technical data
Scope:Heat treatment of titanium components
Charge:Titanium components
Temperature:400 °C - 700 °C
Temperature accuracy:+ / - 6 K
Useful dimensions W x H x D:1800 x 1600 x 1800 mm
Exterior dimensions W x H x D:4780 x 6340 x 5180 mm
Batch Weight:6000 KG
Total weight:18500 KG
Energy:Power
Control:SPS
LoremLipsum

Air circulation furnace for heat treatment of titanium process molds

Technical data
Usable space [W x H x D]: 1.960 x 2.100 x 1.450mm
Heating power:300kW
Fan power:7,5kW, frequency controlled
Insulation thickness:200mm rock wool, 50mm microporous board, lightweight refractory bricks
Working temperature:max. 675 °C +/-6 °C
Temperature accuracy:Furnace class 2, +/-6 °C
Heating:Gas
Plant size [W x H x D]: 5,10 x 7,42 x 8,54m
LoremLipsum

Air circulation furnace for magnesium heat treatment

Technical data
Usable space [W x H x D]: 800 x 800 x 750mm
Heating power:36kW
Fan power:4kW, frequency controlled
Insulation thickness:250mm
Max. Working temperature:630 °C
Batch cooling:Blower: 2,5kW
Heating:Electrical, under inert gas atmosphere
Plant size [W x H x D]: 4,043 x 2,807 x 2,153m
LoremLipsum

Continuous furnaces

Continuous system for the heat treatment of aluminum parts | Romania

Technical data
Number of oven zones:LGO: 7 ALO: 7
Charging rack dimensions [L x W x H]:1400 x 1090 x 500 mm
Number of charging racks in the ovenIn LGO: 14 In ALO: 28
Heating capacity:LGO 228 kW ALO 202 kW
Fan performance:LGO 7x 7.5 kW, frequency-controlled ALO 7x 7.5 kW, frequency-controlled
Throughput:230 / 400 kg/h
Insulation thickness:200 mm
Temperature range:LGO 380 - 550 °C +/-4 K ALO 150 - 350 °C +/-4.5 K
Air deterrent:Blower 4x 7.5 kW
Heating:Electric
System size [L x W x H]:21.30 x 7.35 x 7.70 m
  • LGO = Solution annealing furnace
  • ALO = Ageing furnace

Continuous oven

Technical data
Scope:Water management
Charge:Steel castings
Temperature:100°C bis 350 °C
Useful dimensions:1200 x 1100 x 3300 mm
Temperature accuracy:+/-5 °K
LoremLipsum

Annealing furnace | GERMANY

Technical data
Usable space [W x H x D]:1.250 x 1.550 x 2.500mm
Heating power: 81kW
Fan power:2x 5,5kW, frequency controlled
Insulation thickness:200mm rock wool + 50mm microporous board
Temperature range:110 - 430°C +/-5 °C
Temperature accuracy:Furnace class 2, +/-5 °C
Instrumentation: AMS2750 D
Heating:Electric
Plant size [W x H x D]:3,15 x 5,02 x 8,40m
LoremLipsum

Continuous oven for curing silicone seals | GERMANY

Technical data
Usable space [W x H x D]: 940 x 200 x 2.240mm
Heating power: 12kW
Fan power:2x 0.6/2.5kW, frequency controlled
Insulation thickness:100mm; cooling chamber: 50mm
Working temperature: max. 150°C
Heating:Electric
Plant size [W x H x D]:1,87 x 1,97 x 4,20m
LoremLipsum

Continuous plant for heat treatment of aluminum parts | GERMANY

Technical data
Clear dimensions of the furnace chamber [L x W x H]:LGO 20.700 x 3.975 x 750mm
ALO 18.600 x 3.975 x 750mm (2x)
Number of furnace zones:LGO: 10
ALO: 9
Heating power:LGO 960kW
ALO 600kW
Fan power:LGO 10x 22kW, frequency controlled
ALO 9x 22kW, frequency controlled
Throughput:150 parts
Insulation thickness:200mm
Temperature range:LGO 300 - 520 °C +/-3K
ALO 120 - 250 °C +/-3K
Air Deterrence:15.400 x 6.900 x 11.800mm, blower 4 x 37kW
Temperature accuracy:Furnace class 1
Heating:Electric
Plant size [L x W x H]:39,3 x 7,7 x 11,8m
LoremLipsum
  • LGO = Solution annealing furnace
  • ALO = Ageing furnace

Continuous furnace | GERMANY

Technical data
Usable space [W x H x D]:LGO 7.970 x 1.600 x 800mm
ALO 12.750 x 3.315 x 800mm
Heating power:LGO 342kW
ALO 461kW
Fan power:LGO 5x 22kW, frequency controlled
ALO 8x 22kW, frequency controlled
Throughput:780kg/h
Insulation thickness:250mm
Temperature range:LGO 450 - 550 °C +/-5K
ALO 120 - 220 °C
Water quenching basin:21m³, 35°C - to boiling water
Temperature accuracy:Furnace class 1, AMS2750E, +/-3C
Instrumentation:Instrumentation type C according to AMS2750E
Heating:Electric
Plant size [L x W x H]:41,20 x 11,40 x 6,97m
LoremLipsum
  • LGO = Solution annealing furnace
  • ALO = Ageing furnace

Continuous system for the heat treatment of aluminum parts | GERMANY

Technical data
Usable space [W x H x D]:LGO 19.000 x 3.200 x 1.405mm
ALO 13.300 x 3.200 x 3.705mm
Heating power:LGO 600kW gas + 279,6kW electric
ALO 440kW gas + 210kW electric
Fan power:LGO 20x 7,5kW, frequency controlled
ALO 1x 22kW + 6x 15kW, frequency controlled
Insulation thickness:250mm
Temperature range:LGO 400 - 540 °C
ALO 120 - 280 °C
Air Deterrence:8.300 x 11.100 x 13.400mm, blower 4 x 15kW
Temperature accuracy:Furnace class 1, +/-3C
Instrumentation:Instrumentation type C according to AMS2750E
Heating:Gas + electric
Plant size [L x W x H]:28,3 x 18,0 x 12,0 m
LoremLipsum
  • LGO = Solution annealing furnace
  • ALO = Ageing furnace

Continuous system for the heat treatment of aluminum parts | AUSTRIA

Technical data
Usable space [W x H x D]:LGO 2x 1.800 x 1.600 x 600mm
ALO 4x 1.800 x 1.600 x 600mm
Heating power:LGO 1.020kW
ALO 870kW
Fan power:LGO 9x 22kW, frequency controlled
ALO 9x 22kW, frequency controlled
Number of furnace zones:LGO: 9
ALO: 9
Insulation thickness:250mm
Temperature range:LGO 300 - 520°C
ALO 120 - 230°C
Usable space air shower [L x W x H]:2x 1.800 x 1.600 x 600mm; blower: 4x 37kW
Temperature accuracy:Furnace class 2 - LGO: +/-4 °C, ALO: +/-4.5 °C
Instrumentation:Instrumentation type C according to AMS2750E
Heating:Electric
Plant size [L x W x H]:34,54 x 8,50 x 10,55 m
LoremLipsum
  • LGO = Solution annealing furnace
  • ALO = Ageing furnace

Continuous system for the heat treatment of aluminum parts | CZECHIA

Technical data
Usable space [W x H x D]:LGO 12.000 x 1.350 x 1.800mm
2x ALO 11.500 x 1.350 x 1.800mm
Heating power:LGO 622,4kW
2x ALO 373kW
Fan power:LGO 6x 15kW, frequency controlled
2x ALO 6x 15kW, frequency controlled
Throughput per h:144 parts
Insulation thickness:250mm
Temperature range:LGO 150 - 550°C
2x ALO 120 - 430°C
Air quench [L x W x H]:3.800 x 3.330 x 7.800mm, blower 4 x 30kW
Temperature accuracy:Furnace class 1, +/-2C - +/-3C
Instrumentation:Instrumentation type C according to AMS2750E
Heating:Electric
Plant size [L x W x H]:27,3 x 13,5 x 7,8m
LoremLipsum
  • LGO = Solution annealing furnace
  • ALO = Ageing furnace

Continuous system for the heat treatment of aluminum parts | GERMANY

Specifications
Usable space [W x H x D]:LGO 12,000 x 2,340 x 670mm
ALO 12,000 x 2,340 x 670mm
Heating capacity:LGO 330kW
ALO 276kW
Fan power:LGO 8x 7.5kW, frequency controlled
ALO 8x 7.5kW, frequency controlled
Number of oven zones:LGO: 8
ALO: 8
Insulation thickness:200mm
Temperature range:LGO 150 - 530 °C
ALO 120 - 400 °C
Air deterrent [L x W x H]:4,000 x 7.45 0 x 6,950mm; Blower: 4x 11kW
Temperature accuracy:Oven class 2 +/-4°C
Heating:Electric
System size [L x W x H]:approx. 24.5 x 5.8 x 8.0m
LoremLipsum
  • LGO = Solution annealing furnace
  • ALO = Ageing furnace

Continuous system for the heat treatment of aluminum parts | AUSTRIA

Technical data
Usable space per zone [W x H x D]:LGO 2x 1,800 x 1,600 x 600mm
ALO 4x 1,800 x 1,600 x 600mm
Heating capacity:LGO 864kW
ALO 568kW
Fan power:LGO 8x 22kW, frequency controlled
ALO 8x 22kW, frequency controlled
Insulation thickness:250mm
Temperature range:LGO 300 - 520 °C +/-5K
ALO 120 - 230 °C
Usable space air shower [L x W x H]:2x 1,800 x 1,600 x 600mm; Blower: 4x 37kW
Temperature accuracy:Oven class 2 - LGO: +/- 4 °C, ALO: +/-4.5 °C
Heating:Electric
System size [L x W x H]:29, 5 x 8.25 x 9.9m
LoremLipsum
  • LGO = Solution annealing furnace
  • ALO = Ageing furnace

Continuous flow system for heat treatment of aluminum parts | VR CHINA

Technical data
Usable space per zone [W x H x D]:LGO 2x 1,160 x 1,090 x 670mm
ALO 2x 1,160 x 1,090 x 670mm
Heating capacity:LGO 312kW
ALO 226kW
Fan power:LGO 7x 7.5kW, frequency controlled
ALO 7x 7.5kW, frequency controlled
Number of oven zones:LGO: 7
ALO: 7
Throughput:46 batches
Insulation thickness:200mm
Temperature range:LGO 380 - 550°C
ALO 150 - 350°C
Useful space air shower [L x W x H]:2x 1,160 x 1,090 x 670mm; Blower: 4x 7.5kW
Temperature accuracy:Oven class 2 - LGO: + /-4 °C, ALO: +/-4.5 °C
Heating:Electric
System size [L x W x H]: 21.30 x 7.35 x 7.70m
LoremLipsum
  • LGO = Solution annealing furnace
  • ALO = Ageing furnace

Continuous system for the heat treatment of aluminum parts | USA

Technical data
Usable space: LGO 16,200 x 1,600 x 600mm
ALO 16,200 x 1,600 x 1,200mm
Heat output: LGO 930kW
ALO 738 kW
Fan power: LGO 8x 22kW, frequency controlled
ALO 8x 22kW, frequency controlled
Throughput:1,044,000 pieces
Insulation thickness:250mm
Temperature range:LGO 300 - 520 °C
ALO 120 - 260 °C
Requirement:TL 117C
Air check:187kW
Cooling gradient:475°C to 300°C in 35 sec. (5.0°C /sec.)
300°C to 150°C in 45 sec. (3.5°C/sec.)
150°C to 50°C in 75 sec. (1.2°C/sec .)
Temperature accuracy:Oven class 1, +/-3C
Heating:Electric
System size [L x W x H]:30.97 x 10.97 x 12.90m
LoremLipsum
  • LGO = Solution annealing furnace
  • ALO = Ageing furnace

Continuous system for the heat treatment of aluminum parts | AUSTRIA

Technical data
Usable space per zone [L x W x H]:LGO 2x 1,800 x 1,600 x 600mm
ALO 4x 1,800 x 1,600 x 600mm
Heating capacity:LGO 736kW
ALO 610kW
Fan power:LGO 6x 22kW, frequency controlled
ALO 6x 22kW, frequency controlled
Number of oven zones:LGO: 6
ALO: 6
Insulation thickness:250mm
Temperature range:LGO 300 - 520 °C
ALO 120 - 230 °C
Usable space air shower [L x W x H]:2x 1,800 x 1,600 x 600mm; Blower: 4x 37kW
Temperature accuracy:Oven class 2 - LGO: +/- 4 °C, ALO: +/-4.5 °C
Heating:Electric
System size [L x W x H]: 26, 8 x 7.80 x 9.9m
LoremLipsum
  • LGO = Solution annealing furnace
  • ALO = Ageing furnace

Continuous flow system for heat treatment of aluminum parts | VR CHINA

Specifications
Heating capacity: LGO 662kW
ALO 778kW
Fan power:LGO 4x 22kW, frequency controlled
ALO 4x 22kW, frequency controlled
Number of oven zones:LGO: 4
ALO: 4
Insulation:250mm
Temperature range:LGO 150 - 550 ° C
ALO 120 - 400 °C
Air shower cooling capacity:4x 37kW
Heating:Electric
System size [L x W x H]:27.0 x 10.0 x 6.6m
LoremLipsum
  • LGO = Solution annealing furnace
  • ALO = Ageing furnace

Overhead ovens

Overhead system

Overhead furnace system for solution annealing of aluminum parts
Technische Daten
Nutzraum [B x H x T]:1.100 x 2.020 x 4.000 mm
Heizleistung:303 kW
Lüfterleistung:3x 22 kW, frequenzgeregelt
Chargengewicht:500 kg Aluminium / 400 kg Stahl
Isolierstärke:200 mm
Max. Ofentemperatur600 °C
Max. Arbeitstemperatur:550 °C
KühlungGlykol Abschreckbecken
Ausführungnach AMS 2750 G
Temperaturgenauigkeit:Ofenklasse 2, +/-6 °C
Instrumentierungstyp:D
Beheizung:elektrisch
Anlagengröße [B x H x T]:18,7 x 7,6 x 7,0 m

Overhead system

Specifications
Application: Aircraft industry, aluminum industry
Charge:Aluminium plates
Temperature:100° C to 220°C
Useful dimensions:2000 x 2000 x 9200 mm
batch weight:up to 40000 kg
Temperature Accuracy:+/-3°K
Lorem Lipsum

Overhead system

Specifications
Application: Automotive
Charge:clutch and brake discs
Temperature:100 °C to 800°C
Batch dimensions:1300 x 1100 mm
Batch weight:up to 3000 kg
Temperature accuracy:+/-5°K
LoremLipsum

Overhead system

Specifications
Application: Aluminum industry
Charge:Aluminum parts
Temperature:100°C to 540°C
Useful dimensions:880 x 1000 x 2000 mm
Batch weight:up to 600 kg
Temperature accuracy:+/-5°K
LoremLipsum

Overhead system

Overhead furnace system for heat treatment of aluminum plates for the aerospace industry according to AMS 2750.
Specifications
max. Oven temperature:300°C
max. Working temperature:250°C
External dimensions L x W x H:15350 x 4650 x 13050 mm
Oven work space:13100 x 2510 x 2000 mm
Internal volume of the oven chambers:92.6 m³
Heating device - heating power:504 kW
Fan unit - motor power:6 pieces, 37 kW
LoremLipsum

Overhead heat treatment plant for retrieval of aluminum parts | AUSTRIA

Specifications
Usable space [W x H x D]:13,100 x 2,510 x 2,000mm300°C
Heat output:504kW
Fan performance: 6x 37kW, frequency controlled
Insulation thickness:250mm
Temperature range:: 110 - 250°C
Cooling:Downstream cooling chamber with supply and exhaust air system
Temperature accuracy:AMS 2750, oven class 1 , +/-3°C
Heating: Electrical
System size [W x H x D ]: 31.5 x 19.7 x 13.2m
LoremLipsum

Overhead system for tempering aluminum parts | SWITZERLAND

Specifications
Usable space [W x H x D]: 4,000 x 2,020 x 1,100mm
Heat output: 297.4 kW
Fan performance: 3x 22kW, frequency controlled
Batch weight: 500 kg aluminum / 400 kg steel
Insulation thickness: 200mm
Temperature range: 100 - 550°C
Water Quench Tank: on-site
Temperature Accuracy: Oven class 2, AMS2750E, +/-5°C
Instrumentation:AMS2750E
Heating: Electrical
System size [W x H x D]: 15.6 x 5.36 x 9.26m
LoremLipsum

Overhead plant for heat treatment of aluminum parts | AUSTRIA

Specifications
Usable space [L x W x H]: 13,100 x 2,510 x 2,000mm
Heat output: 504kW
Fan performance:6x 37kW, frequency controlled
Insulation thickness: 250mm
Working temperature: max. 250°C
Cold chamber: after the aging furnace
Heating: Electric
Attachment size [B x H x D]: 31.5 x 19.7 x 13.2m
LoremLipsum

Extension of an overhead plant for heat treatment of aluminum parts | AUSTRIA

Specifications
Useful dimensions of the oven chamber/extension [L x W x H]: 7,000 x 1,600 x 2,480mm
Heat output: 312kW
Fan power: 4x 11kW, frequency controlled
Insulation thickness:150mm
Temperature range: 100 - 220°C
Heating: Electric
Attachment size [W x H x D]:64.20 x 61.00 x 10, 10m
LoremLipsum

Bogie hearth furnaces

Bogie hearth furnace

Specifications
Application: Ceramics industry
Charge: Firebricks
Temperature:100°C to 680°C
Useful dimensions:2500 x 2500 x 5000 mm
Batch weight:up to 20000 kg
LoremLipsum

Bogie hearth furnace

Specifications
Application: University
Charge:Miscellaneous
Temperature:100°C to 950°C
Useful dimensions:1000 x 1000 x 1500 mm
Lorem< /td>Lipsum

Bogie hearth furnace | GERMANY

Specifications
Usable space:L x W x H = 3,000 x 3,000 x 13,600mm
Heat output:900kW
Fan performance: 8x 22kW, frequency controlled
Airflow: 8 zones with air reversal
Batch weight:40t
Insulation thickness: 250mm
Temperature range:90 - 250°C
Temperature Accuracy: Oven class, AMS2750E, +/-2°C
Instrumentation: Instrumentation type C according to AMS2750E
Heating: Electric
Attachment size: L x W x H = 30.4 x 5.6 x 7.5m
LoremLipsum

Chest oven

Chest oven

This furnace is used to preheat aluminum press tool.
Specifications
Application: Aluminium industry
Charge: Pressing tools for aluminum
Temperature:up to 500°C
Useful dimensions:1000 x 720 x 600mm
Batch weight:max. 900 kg
LoremLipsum

Chamber kilns, kilns & double-door kilns

Kiln

The robust as well as compact design of the furnace allows a perfect use as a test furnace in the laboratory of a university.
Specifications
Application: University
Batch:ceramic, porcelain
Temperature:100°C to 1300 °C
Interior: 400 x 300 x 600 mm
Batch weight:variable
LoremLipsum

Chamber oven with lifting door

Chamber furnace for the heat treatment of forged parts
Technical data
Batch:Steel parts
Max. oven temperature:820 °C
Max. working temperature:790 °C
Temperature accuracy:+ / - 5 K
External dimensions: W x H x D:4395 x 4110 x 3135 mm
Usable dimensions of the oven chamber w x h x d:2200 x 1200 x 1000 mm
Useful volume of the oven chamber:3,5 m³
Heating device / heat output:120 kW
Fan unit / motor power:1 piece; 7.5 kW
Special features:Shielding gases (nitrogen, forming gas) and shielding gas recooling

Chamber furnace with lift door

Specifications
Application: Plastics industry
Charge:Molybdenum plates
Temperature:300°C up to 1200°C
Batch measurements:1600 x 3600 x 4-20 mm
batch weight:max. 3000 kg
Temperature accuracy:+/-15°K
Lipsum

Chamber furnace

Chamber furnace for heat treatment of ceramic components
Specifications
max. Oven temperature:820°C
max. Working temperature:800°C
External dimensions W x H x D:1820 x 2780 x 1920 mm
Useful dimensions of the oven chamber W x H x D:895 x 680 x 1385 mm
Useful volume of the oven chambers:approx. 0.85 m³
Heating device / heating capacity:48 kW
Fan unit / motor power:1.5 kW
LoremLipsum

Chamber furnace

Chamber furnace for heat treatment of titanium sheets for the aerospace industry according to AMS 2750
Specifications
max. Oven Temperature:720°C
max. Working temperature:675°C
External dimensions W x H x D:5100 x 7420 x 8540 mm
Useful dimensions of the oven chamber W x H x D:1960 x 2100 x 1450 mm
Useful volume of the oven chambers:5.97 m³
Heating device / heating power: 2 pieces each 150 kW
Fan unit / Motor power:7 .5 kW
LoremLipsum

Laboratory furnace | PR CHINA

Specifications
Usable space [W x H x D]: 500 x 500 x 500mm
Heat output: 12 kW
Fan performance :1.5kW
Insulation thickness:100mm Rockwool, 50mm Microporous Insulation Board
Working temperature: max . 650°C
Heating:
Electric
System size [W x H x D]: 1.15 x 2.40 x 1.08m
LoremLipsum

annealing furnace | AUSTRIA

Specifications
Usable space [W x H x D]:800 x 600 x 1,200mm
Heat output: 48kW
Insulation thickness: 200mm
Working temperature: max. 1,300°C
Heating:
Electric
Other: Storage grate; Lifting door with weight compensation
System size [W x H x D]: 1.915 x 3.075 x 2.031m
Lorem Lipsum

Pit furnaces & crucible furnaces

Shaft furnace

Specifications
Application: Aluminum industry
Charge:Aluminum Wire
Temperature:up to 600°C
Internal dimensions:d=900 mm; h=1500 mm
batch weight:max. 500 kg
Temperature accuracy:
+/-3°K
LoremLipsum

Shaft furnace

Specifications
Application: Aluminum industry
Charge:Transmission housing
Internal dimensions:160°C up to 560°C
Useful dimensions:d=1500 mm ; h=2500 mm
batch weight:max. 880 kg
Temperature accuracy:+/-2°K
Lipsum

Furnaces for welding consumables

Welding powder dryer | AUSTRIA

Specifications
Usable space [W x H x D]:490 x 1,050 x 640mm
Oven chamber:drying chamber + holding chamber
Heating power:4.8kW - drying chamber, 2.7kW - holding chamber
Chamber capacity:2 x 83 l
Insulation thickness: 150mm
Working temperature< /span>:max. 400°C drying chamber, max. 250°C holding chamber
Heating:
Electric
Attachment size:
1.24 x 1.95 x 1.15m
LoremLipsum

Welding powder drying furnace

Specifications
Application: Welding
Charge:Welding consumables
Temperature:400°C / 250°C
Interior:2 x 83 l
LoremLipsum

Welding powder dryer

Welding flux dryer for submerged arc welding for pipelines in power plant construction
Specifications
max. Upper chamber temperature:400°C
max. Lower chamber temperature:250°C
Working temperature:400°C
External dimensions [W x H x D]:1240 x 1950 x 1150 mm
Useful dimensions of the oven chamber [W x H x D]: 490 x 1050 x 640 mm
Usable volume of the furnace chamber [l]:2x 83
Heating device upper chamber / heating power:4.8 kW
Lower chamber heater / Heat output:2.7 kW
LoremLipsum

Pressing furnaces

Press furnace for heat treatment of saw blades | Poland

Technical data
Useful space [L x W x H]:1000x1000x1000 mm
Heating capacity:90 kW
Fan performance:7 kW
Net reference load:3000 kg
Press-Kraft:5 x 20 tons or 1 x 100 tons
Insulation thickness:250 mm
Working temperature:550 °C
Batch cooling:Blower: 2x 5.5 kW
Heating:Electrical, under inert gas atmosphere
System size [W x H x D]:3.24 x3.42 x 3.81 m

Pressing furnace

This furnace is used to bring saw blades to temperature in a protective atmosphere.
Specifications
Application: Saw blade manufacturer
Charge:Saw blades
Temperature:up to 600°C
Usable oven length:approx. 5200 mm
LoremLipsum

Press furnace for heat treatment of saw blades | POLAND

Specifications
Usable space [L x W x H]: 1,000 x 1,000 x 1,000mm
Heat output:90kW
Fan performance: 7.5kW, frequency controlled
Net reference load: 2,100kg
Hydraulic press unit: 3.0kW
Insulation thickness: 250mm
Working temperature: max. 600°C
Batch cooling: Fan: 2x 3kW
Heating: Electric, under protective gas atmosphere
Attachment size [W x H x D]:3.10 x 3.36 x 3.48m
LoremLipsum

Air circulation furnace for magnesium heat treatment

Specifications
Usable space [L x W x H]: 1,000 x 1,000 x 1,000mm
Heating power: 90kW
Fan power: 7.5kW, frequency controlled
Net reference load:2,100 kg
Hydraulic press unit:5.5kW
Insulation thickness: 250mm
Working temperature: max. 600°C
Batch cooling: Fan: 2x 3kW
Heating: Electric, in a protective gas atmosphere
System size [W x H x T]: 3.105 x 3.40 x 3 ,45m
LoremLipsum< /td>

Cable preheating furnaces

Cable preheating furnace

Technische Daten
Anwendungsbereich:Kabelhersteller
Charge:Kabel
Temperatur:bis 400 °C
Nutzbare Ofenlänge:2050 mm
Heizleistung:12 kW

Cable preheating furnace

Technische Daten
Anwendungsbereich:Kabelhersteller
Charge:Kabel
Temperatur:bis 400 °C
Nutzbare Ofenlänge:1080 mm
Heizleistung:3 kW
HOFMANN Wärmetechnik GmbH
Gewerbezeile 7 4202 Hellmonsödt Austria
+43 7215 36 01
+43 7215 36 01 60
Company
  • General delivery conditions
  • Terms and conditions of purchase
  • Maintenance conditions
Product portfolio
  • Industrial furnaces
  • Ovens in stock
  • References
  • News
  • Company
  • Career
  • Request
  • Contact
  • Sitemap
  • News
  • Imprint
  • Privacy policy
Inquiry form
HOFMANN Wärmetechnik GmbH
Gewerbezeile 7 4202 Hellmonsödt Austria
+43 7215 36 01
+43 7215 36 01 60